期刊论文详细信息
BMC Ophthalmology
Intra- and interobserver concordance of a new classification system for myopic maculopathy
Yin-fen Hou1  Chang-fan Wu1  Yan Yu1  Rong-rong Zhang1 
[1] Department of Ophthalmology, Yijishan Hospital of Wannan Medical College, 92 West Zheshan Road, 241001, Wuhu, Anhui Province, People’s Republic of China;
关键词: High myopia;    Myopic maculopathy;    ATN classification;    Optical coherence tomography;    Agreement study;   
DOI  :  10.1186/s12886-021-01940-4
来源: Springer
PDF
【 摘 要 】

BackgroundMyopic maculopathy (MM) is one of the major causes of visual impairment and irreversible blindness in eyes with pathologic myopia (PM). However, the classification of each type of lesion associated with MM has not been determined. Recently, a new MM classification system, known as the ATN grading and classification system, was proposed; it is based on the fundus photographs and optical coherence tomography (OCT) images and includes three variable components: atrophy (A), traction (T), and neovascularization (N). This study aimed to perform an independent evaluation of interobserver and intraobserver agreement for the recently developed ATN grading system for MM.MethodsThis was a retrospective study. Fundus photographs and OCT images of 125 patients (226 eyes) with various MMs were evaluated and classified using the ATN grading of the new MM classification system by four blinded and independent evaluators (2 attending ophthalmologists and 2 ophthalmic residents). All cases were randomly re-evaluated by the same observers after an interval of 6 weeks. The kappa coefficient (κ) and 95% confidence interval (CI) were used to determine the interobserver and intraobserver agreement.ResultsThe interobserver agreement was substantial when considering the maculopathy type (A, T, and N). The weighted Fleiss κ values for each MM type (A, T, and N) were 0.651 (95% CI: 0.602–0.700), 0.734 (95% CI: 0.689–0.779), and 0.702 (95% CI: 0.649–0.755), respectively. The interobserver agreement when considering the subtypes was good or excellent, except for stages A1, A2, and N1, in which the weighted κ value was less than 0.6, with moderate agreement. The intraobserver agreement of types and subtypes was excellent, with κ > 0.8. No significant differences were observed between the attending ophthalmologists and residents for interobserver reliability or intraobserver reproducibility.ConclusionsThe ATN classification allows an adequate agreement among ophthalmologists with different qualifications and by the same observer on separate occasions. Future prospective studies should further evaluate whether this classification can be better implemented in clinical decision-making and disease progression assessments.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO202107030134542ZK.pdf 2265KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:9次