期刊论文详细信息
Revista Brasileira de Oftalmologia
Pseudoaccommodating bifocal intraocular lens implantation in eyes with previous corneal refractive surgery - refractive outcomes: case series of 8 eyes
Giuliano De Oliveira Freitas2  Natália De Oliveira Faria1  Joel Edmur Boteon1  Mario José Carvalho1 
[1] ,Universidade Federal de Minas GeraisBelo Horizonte MG ,Brazil
关键词: Phacoemulsification;    Lens implantation;    intraocular;    Cornea;    Biometry;    Refraction;    Ocular;    Facoemulsificação;    Implante de lente intraocular;    Córnea;    Biometria;    Refração ocular;   
DOI  :  10.1590/S0034-72802010000500006
来源: SciELO
PDF
【 摘 要 】

OBJECTIVE: Accurate intraocular lens power calculation may be a challenging issue in eyes with previous corneal refractive surgery. METHODS: The authors present a series of 8 eyes (4 previously submitted to hyperopic laser in situ keratomileusis and 4 to radial keratectomy) submitted to phacoemulsification and implantation of pseudoaccommodating bifocal intraocular lens. Double-K SRK/T formula has been used. RESULTS: Acceptable refractive visual outcomes have been achieved. CONCLUSION: Pseudoaccommodating bifocal intraocular lenses can be safely implanted in patients with previous corneal refractive surgery.

【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130022588ZK.pdf 82KB PDF download