期刊论文详细信息
Arquivos Brasileiros de Oftalmologia
Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
Teresa Ferrer-blasco1  Santiago García-lázaro1  César Albarrán-diego1  Lurdes Belda-salmerón1  Robert Montés-micó1 
[1] ,University of Valencia Optics Department ,Spain
关键词: Lens implantation;    intraocular;    Lens;    crystalline;    Myopia;    Hyperopia;    Phacoemulsification;    Prosthesis design;    Tonometry;    ocular;    Visual acuity;    Implantação de lentes intraoculares;    Cristalino;    Miopia;    Hipermetropia;    Hipermetropia;    Desenho de próteses;    Acuidade visual;   
DOI  :  10.1590/S0004-27492012000300009
来源: SciELO
PDF
【 摘 要 】

PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively). The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group). CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.

【 授权许可】

CC BY   
 All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License

【 预 览 】
附件列表
Files Size Format View
RO202005130003444ZK.pdf 415KB PDF download
  文献评价指标  