Food and Agricultural Immunology | |
Immunochromatographic paper sensor for ultrasensitive colorimetric detection of cadmium | |
Shuzhen Zou1  Hua Kuang1  Shanshan Song1  Jianping Zhu1  Liqiang Liu1  | |
[1] State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, Jiangsu, People’s Republic of Chin;Collaborative Innovation Center of Food Safety and Quality Control in Jiangsu Province, Jiangnan University, Wuxi, Jiangsu, People’s Republic of Chin; | |
关键词: Cadmium; immunochromatographic strip; monoclonal antibody; gold-nanoparticle (GNP); | |
DOI : 10.1080/09540105.2017.1354358 | |
来源: publisher | |
【 摘 要 】
A novel and highly sensitive immunochromatographic strip based on a monoclonal antibody (3A9) was developed for the detection of cadmium in tap water. The 50% inhibition concentration of the antibody, which showed no cross-reactivity with other heavy metal ions, was 0.45 ng/mL and it recognized Cd(II)–1-(4-isothiocyanobenzyl) ethylenediamine-N,N,N′,N′-tetraacetic acid (EDTA) (Cd(II)–ITCBE) and not metal-free ITCBE and EDTA. The cutoff value for semi-quantitative detection of the strip was 5 ng/mL and the lower limit of detection for quantitative detection was 0.2 ng/mL using a scanning reader. The percent recovery ranged from 107.6% to 132% in tap water samples.
【 授权许可】
CC BY
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202004234213828ZK.pdf | 1335KB | download |