An Investigation of Glutathione-Platinum(II) Interactions by Means of the Flow Injection Analysis Using Glassy Carbon Electrode | |
Ondrej Zitka2  Dalibor Huska2  Sona Krizkova2  Vojtech Adam2  Grace J. Chavis5  Libuse Trnkova3  Ales Horna4  Jaromir Hubalek1  | |
[1] Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Udolni 53, CZ-602 00 Brno, Czech Republic;Department of Chemistry and Biochemistry, Faculty of Agronomy, Mendel University of Agriculture and Forestry, Zemedelska 1, CZ-613 00 Brno, Czech Republic;Department of Chemistry, Faculty of Science, Masaryk University Kotlarska 2, CZ-611 37 Brno, Czech Republic;Department of Food Engineering, Faculty of Technology, Tomas Bata University, T.G. Masaryka 275, CZ-762 72 Zlin, Czech Republic;Department of Chemistry, University of California, One Shields Avenue, CA-956 16 Davis, USA | |
关键词: Glutathione; Carbon paste electrode; Thiols; Cisplatin; Cancer; Flow injection analysis with electrochemical detection; | |
DOI : 10.3390/s7071256 | |
来源: mdpi | |
【 摘 要 】
Despite very intensive research in the synthesising of new cytostatics, cisplatin is still one of the most commonly used anticancer drugs. Therefore, an investigation of interactions of cisplatin with different biologically important amino acids, peptides and proteins is very topical. In the present paper, we utilized flow injection analysis coupled with electrochemical detection to study and characterize the behaviour of various forms of glutathione (reduced glutathione – GSH, oxidized glutathione – GSSG and S-nitroso glutathione – GSNO). The optimized conditions were as follows: mobile phase consisted of acetate buffer (pH 3) with a flow rate of 1 mL min-1. Based on results obtained we chose 850 mV as the optimal potential for detection of GSH and 1,100 mV as the optimal potential for detection of GSSG and GSNO. The detection limits of GSH, GSSG and GSNO were 100 pg mL-1, 50 ng mL-1 and 300 pg mL-1, respectively. Further, the optimized technique was used for investigation of interactions between cisplatin and GSH. We were able to observe the interaction between GSH and cisplatin via decrease in the signal corresponding to glutathione. Moreover, we evaluated the formation of the complex by spectrometry. The spectrometric results obtained were in good agreement with electrochemical ones.
【 授权许可】
Unknown
© 2007 by MDPI (
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202003190059237ZK.pdf | 245KB | download |