Energy Saving Characteristics of the Internally Heat Integrated Distillation Column (HIDiC) Pilot Plant for Multicomponent Petroleum Distillation
Masaru Nakaiwa4  Kinpei Horiuchi2  Keigo Matsuda3  Kiro Yanagimoto5  Koichi Iwakabe5  Kunio Kataoka1 
[1] Kansai Chemical Engineering Co., Ltd., R&D Research Center;Maruzen Techno-Service Co., Ltd.;Department of Chemistry and Chemical Engineering, Graduate School of Science and Engineering, Yamagata University;Research Institute for Innovation in Sustainable Chemistry, National Institute of Advanced Industrial Science and Technology;E&E Planning Co., Ltd.
关键词: Heat Integrated Distillation Column;    Energy Saving;    Pilot Plant;    Simulation;   
DOI  :  10.1252/jcej.08we017
来源: Maruzen Company Ltd
PDF
【 摘 要 】

References(16)Cited-By(6)Internally heat-integrated distillation columns (HIDiCs) are one of the most attractive alternatives for the conventional distillation columns (CDiCs) since HIDiCs have very high potential to separate a mixture with smaller energy consumption compared to CDiCs. In order to prove the energy saving characteristics of HIDiCs, a pilot plant of the HIDiC was constructed for the separation of multicomponent hydrocarbon mixture. The HIDiC pilot plant was operated at zero external reflux condition, and achieved more than 50% reduction in the energy consumption compared to the simulation results of the existent CDiC.