期刊论文详细信息
Química Nova | |
Fast determination of basic drugs in plasma by gas chromatography with nitrogen phosphorus detector | |
Linden, Rafael1  Silva, Luana Letícia da1  Lanaro, Rafael1  Lizot, Lilian Feltraco1  Antunes, Marina Venzon1  Universidade Estadual de Campinas, Campinas, Brasil1  Universidade Feevale, Novo Hamburgo, Brasil1  Spaniol, Bárbara1  | |
关键词: GC-; NPD; emergency toxicology; drug screening.; | |
DOI : 10.1590/S0100-40422012000600029 | |
学科分类:化学(综合) | |
来源: Sociedade Brasileira de Quimica | |
【 摘 要 】
A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912050595771ZK.pdf | 424KB | download |