Journal of the Brazilian Chemical Society | |
Electrochemical oxidation of chlorhexidine and its amperometric determination by flow-injection analysis | |
Richter, Eduardo M.1  Montes, Rodrigo H. O.1  Lima, Ana Paula de1  Silva, Luiz A. J.1  Muñoz, Rodrigo A. A.1  Stefano, Jessica S.1  Cunha, Rafael R.1  Universidade Federal de Uberlândia, Uberlândia, Brazil1  | |
关键词: chlorhexidine oxidation; bare electrode; organochloride; antiseptic; | |
DOI : 10.5935/0103-5053.20130267 | |
学科分类:化学(综合) | |
来源: SciELO | |
【 摘 要 】
The electrochemical oxidation of chlorhexidine is investigated for the first time and its amperometric determination using a flow-injection analysis (FIA) system is demonstrated. An oxidation peak was observed at around 1.3 V in a 0.1 mol L-1 HClO4 solution at a glassy-carbon electrode. The mechanism of the electrochemical oxidation of chlorhexidine is pH-dependent and involves a single-electron transfer possibly via radical cation formation. The FIA parameters were optimized and a detection limit of 0.3 µmol L-1 was obtained. The proposed method was applied in mouth rinses and skin disinfectants samples and compared with high-performance liquid chromatography.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201912050582131ZK.pdf | 200KB | download |