期刊论文详细信息
Developmental Biology
Concentrations of carbon monoxide in indoor and outdoor air of Ghalyun cafes
Ali Rastgu1  Mehdi Fazlzadeh1  Roohollah Rostami2  Sadegh Hazrati1 
[1] Department of Environmental Health Engineering, School of Public Health, Ardabil University of Medical Sciences, Ardabil, Iran$$;Department of Environmental Health Engineering, School of Health, Semnan University of Medical Sciences, Semnan, Iran$$
关键词: Carbon monoxide;    Ghalyun;    indoor;    outdoor;    cafes;   
DOI  :  10.5094/APR.2015.061
学科分类:农业科学(综合)
来源: Dokuz Eylul Universitesi * Department of Environmental Engineering
PDF
【 摘 要 】

Indoor and outdoor carbon monoxide (CO) concentrations were measured in 68 Ghalyun cafes in Ardabil City of Iran. One hour sampling was performed in each location and hourly mean concentrations were reported. Respective mean concentrations of CO in indoor and outdoor air were 24.75±17.17 and 2.65±1.33 ppm with an average indoor to outdoor air concentration ratio of 13.3±13.1. Within the variables studied; type of the tobacco smoked, location of the cafe inside the building, and utilizing mechanical ventilator, respectively, were recognized as the most influential factors controlling CO concentrations in Ghalyun cafes (p<0.05). 73.5% of workers (27.3 and 95.7% of cafes located on ground floors and basements, respectively) were exposed to higher levels of CO than the corrected OEL–TWA (Occupational Exposure Limit) of 10.4 ppm.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912040527901ZK.pdf 631KB PDF download
  文献评价指标  