期刊论文详细信息
Bulletin of the Korean chemical society
Amperometric Immunosensor for Myeloperoxidase in Human Serum Based on a Multi-wall Carbon Nanotubes-Ionic Liquid-Cerium Dioxide Film-modified Electrode
Bei Liu1  Guoming Xie1  Lingsong Lu1  Chenggui Liu1 
关键词: Myeloperoxidase;    Ionic liquid;    Carbon nanotubes;    Cerium dioxide;    Immunosensor;   
DOI  :  
学科分类:化学(综合)
来源: Korean Chemical Society
PDF
【 摘 要 】

A label-free amperometric immunosensor has been proposed for the detection of myeloperoxidase (MPO) in human serum. To fabricate such an immunosensor, a composite film consisting of N,N-dimethylformamide (DMF), multiwall carbon nanotubes (MWCNTs) and 1-ethyl-3-methyl imidazolium tetrafluoroborate (EMIMBF4) suspension was initially formed on a glassy carbon electrode (GCE). Then cerium dioxide (CeO2) dispersed by chitosan was coated on the GCE. After that, MPO antibodies (anti-MPO) were attached onto the nanoCeO2 surface. With a noncompetitive immunoassay format, the antibody-antigen complex formed between the immobilized anti-MPO and MPO in sample solution. The immunosensor was characterized by cyclic voltammetry, transmission electron microscopy (TEM) and scanning electron microscopy (SEM). The factors influencing the performance of the immunosensor were studied in detail. Under optimal conditions, the current change before and after the immunoreaction was proportional to MPO concentration in the range of 5 to 300 ng mL-1 with a detection limit of 0.2 ng mL-1.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010241931ZK.pdf 1055KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:24次