期刊论文详细信息
Journal of Nuclear Medicine
PET Assessment of Myocardial Perfusion Reserve Inversely Correlates with Intravascular Ultrasound Findings in Angiographically Normal Cardiac Transplant Recipients
Yen-Wen Wu1  Kai-Yuan Tzen1  Ming-Fong Chen1  Ruoh-Fang Yen1  Chii-Ming Lee1  Shoei-Shen Wang1  Ying-Hsien Chen1  Hsiang-Yiang Jui1 
关键词: cardiac allograft vasculopathy;    transplantation;    positron emission tomography;    myocardial perfusion quantification;   
DOI  :  10.2967/jnumed.109.073833
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

Cardiac allograft vasculopathy (CAV) is the major determinant of long-term survival after heart transplantation. We aimed to evaluate the efficacy of PET as a noninvasive way to assess the early stages of CAV. Methods: Twenty-seven consecutive patients (20 men and 7 women; mean age ± SD, 46 ± 12 y) who had normal results on coronary angiography and normal left ventricular systolic function (ejection fraction ≥ 60%) were enrolled at 2.5 ± 2.1 y after transplantation. Myocardial blood flow (MBF) was assessed using dynamic 13N-ammonia PET at rest and during adenosine-induced hyperemia, and myocardial perfusion reserve (MPR) was calculated as the ratio of hyperemic MBF to resting MBF. Regional 13N-ammonia PET was assessed using a 5-point scoring system. The intravascular ultrasound (IVUS) measurements for the extent of intimal hyperplasia, including plaque volume index (calculated as [total plaque volume/total vessel volume] × 100%) and maximum area of stenosis, were compared with MPR by linear regression analysis. Results: In 27 angiographically normal cardiac transplant recipients, MBF at rest and during adenosine stress and MPR of the left anterior descending artery distribution correlated strongly with the other 2 coronary artery distribution territories (r ≥ 0.97, P < 0.0001). Summed stress score and summed difference score showed a moderate inverse correlation with MPR (r = −0.41 and −0.49, respectively; P < 0.05) but not with IVUS measurements. MPR correlated inversely with plaque volume index (r = −0.40, P < 0.05) but not with maximal luminal stenosis as assessed by IVUS. In addition, MPR and IVUS measurements gradually inversely changed after heart transplantation (all P < 0.05). Conclusion: This study confirms that CAV is a progressive process, diffusely involving the epicardial and microvascular coronary system. Plaque burden as determined by IVUS agrees well with MPR as assessed by PET in recipients with normal coronary angiography results. This finding suggests that dynamic 13N-ammonia PET is clinically feasible for the early detection of CAV and can be used as a reliable marker of disease progression.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010197779ZK.pdf 1655KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:3次