期刊论文详细信息
Journal of Nuclear Medicine
Atherosclerosis Inflammation Imaging with 18F-FDG PET: Carotid, Iliac, and Femoral Uptake Reproducibility, Quantification Methods, and Recommendations
Ash Rafique1  Sameer Bansilal1  Cathy Anne Pinto1  Valentin Fuster1  Zahi A. Fayad1  Michael Farkouh1  Christopher Tong1  Josef Machac1  Kelly S. Myers1  James H.F. Rudd1  Richard Hargeaves1 
关键词: atherosclerosis;    positron emission tomography;    18F-FDG;    inflammation;    methodology;   
DOI  :  10.2967/jnumed.107.050294
学科分类:医学(综合)
来源: Society of Nuclear Medicine
PDF
【 摘 要 】

Atherosclerosis imaging with 18F-FDG PET is useful for tracking inflammation within plaque and monitoring the response to drug therapy. Short-term reproducibility of this technique in peripheral artery disease has not been assessed, and the optimal method of 18F-FDG quantification is still debated. We imaged 20 patients with vascular disease using 18F-FDG PET twice, 14 d apart, and used these data to assess reproducibility measures and compare 2 methods of 18F-FDG uptake measurement. We also reviewed the literature on quantification methods to determine the optimal measures of arterial 18F-FDG uptake for future studies. Methods: Twenty patients with vascular disease underwent PET/CT of the iliac, femoral, and carotid arteries 90 min after 18F-FDG administration. In 19 patients, repeat testing was performed at 2 wk. Coregistration and attenuation correction were performed with CT. Vessel 18F-FDG uptake was measured as both the mean and maximum blood-normalized standardized uptake value (SUV), known as the target-to-background ratio (TBR). We assessed interscan, interobserver, and intraobserver agreement. Results: Nineteen patients completed both imaging sessions. The carotid and peripheral arteries all have excellent short-term reproducibility of the 18F-FDG signal, with intraclass correlation coefficients all greater than 0.8 for all measures of reproducibility. Both mean and maximum TBR measurements for quantifying 18F-FDG uptake are equally reproducible. 18F-FDG uptake was significantly higher in the carotid arteries than in both iliac and femoral vessels (P < 0.001 for both). Conclusion: We found that both mean and maximum TBR in the carotid, iliac, and femoral arteries were highly reproducible. We suggest the mean TBR be used for tracking systemic arterial therapies, whereas the maximum TBR is optimal for detecting and monitoring local, plaque-based therapy.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201912010197220ZK.pdf 1074KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:18次