期刊论文详细信息
Journal of Veterinary Medical Science
Simultaneous Determination of Tetrahydrofolate and N5-Methyltetrahydrofolate in Pig Plasma by High-Performance Liquid Chromatography with Electrochemical Detection
Minoru SHIMODA1 
关键词: HPLC-ECD;    N5-methyltetrahydrofolate;    pig;    plasma tetrahydrofolate;   
DOI  :  10.1292/jvms.54.249
学科分类:兽医学
来源: Japanese Society of Veterinary Science
PDF
【 摘 要 】

References(16)Cited-By(8)An analytical method for measurement of tetrahydrofolate (THF) and N5-methyltetrahydrofolate (5MF) in pig plasma by the high performance liquid chromatography and electrochemical detection is described. The plasma sample was deproteinized by perchloric acid and the supernatant was analyzed using the following conditions; (a)phenyl bonded phase column as an analytical column; (b)mobile phase consisting of 20mM acetate buffer (pH 3.6) containing 0.1mM EDTA and acetonitrile (96.5:3.5, v/v); (c)an applied potentialof +300mV. Under the above condition, both peaks of THF and 5MF in the plasma were well separated. The detection limits of THF and jMF were 0.15 and 0.13ng/ml, respectively, at S/N=3. The recoveries of THF and 5MF from the plasma spiked with standard THF and 5MF were 77.6±2.1% and 83.0±1.7% (mean±S.D.), respectively.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201911300473269ZK.pdf 701KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:13次