IEICE Electronics Express | |
Calibration of electric field probes in GTEM cell using reference antenna method | |
Kaoru Gotoh1  Yasushi Matsumoto1  Ifong Wu1  Shinobu Ishigami1  | |
[1] EMC Group, National Institute of Information and Communications Technology | |
关键词: electric field probe; reference antenna method; calibration factor; GTEM cell; | |
DOI : 10.1587/elex.6.1469 | |
学科分类:电子、光学、磁材料 | |
来源: Denshi Jouhou Tsuushin Gakkai | |
【 摘 要 】
References(6)Cited-By(1)Calibration of electric field probes in a GTEM cell is carried out using the reference antenna method. To determine the effectiveness of the calibration, we compared our results with those of calibration in an anechoic chamber from 1 to 6GHz. Each electric field probe had three elements, one of which was used to calibrate the other two. The calibration factors in the GTEM cell agree well with those in the anechoic chamber. Therefore, the GTEM cell is as effective as the anechoic chamber for calibrating electric field probes with the same type of probe and helps save more measurement time and effort.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201911300237129ZK.pdf | 1283KB | download |