会议论文详细信息
4th International Conference on Mechanical Engineering Research
Paraffin wax removal from metal injection moulded cocrmo alloy compact by solvent debinding process
Dandang, N.A.N.^1 ; Harun, W.S.W.^2 ; Khalil, N.Z.^2 ; Ahmad, A.H.^3 ; Romlay, F.R.M.^3 ; Johari, N.A.^1
Institute of Postgraduate Studies, Universiti Malaysia Pahang, Lebuhraya Tun Razak, Gambang, Kuantan, Pahang
26300, Malaysia^1
Human Engineering Group, Faculty of Mechanical Engineering, Universiti Malaysia Pahang, Pekan, Pahang
26600, Malaysia^2
Manufacturing Focus Group, Faculty of Mechanical and Materials Engineering, Universiti Malaysia Pahang, Pekan Pahang, Pekan, Pahang
26600, Malaysia^3
关键词: Debinding process;    Metal injection;    Metal injection moulding;    Research studies;    Soaking time;    Solvent debinding;    Surface cracks;    Visual inspection;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/257/1/012020/pdf
DOI  :  10.1088/1757-899X/257/1/012020
来源: IOP
PDF
【 摘 要 】

One of the most crucial and time consuming phase in metal injection moulding (MIM) process is "debinding". These days, in metal injection moulding process, they had recounted that first debinding practice was depend on thermal binder degradation, which demanding more than 200 hours for complete removal of binder. Fortunately, these days world had introduced multi-stage debinding techniques to simplified the debinding time process. This research study variables for solvent debinding which are temperature and soaking time for samples made by MIM CoCrMo powder. Since wax as the key principal in the binder origination, paraffin wax will be removed together with stearic acid from the green bodies. Then, debinding process is conducted at 50, 60 and 70°C for 30-240 minutes. It is carried out in n-heptane solution. Percentage weight loss of the binder were measured. Lastly, scanning electron microscope (SEM) analysis and visual inspection were observed for the surface of brown compact. From the results, samples debound at 70°C exhibited a significant amount of binder loss; nevertheless, sample collapse, brittle surface and cracks were detected. But, at 60°C temperature and time of 4 hours proven finest results as it shows sufficient binder loss, nonappearance of surface cracks and easy to handle. Overall, binder loss is directly related to solvent debinding temperature and time.

【 预 览 】
附件列表
Files Size Format View
Paraffin wax removal from metal injection moulded cocrmo alloy compact by solvent debinding process 439KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:22次