会议论文详细信息
International Conference on Advances in Materials and Manufacturing Applications 2016
Monte-Carlo based Uncertainty Analysis For CO2 Laser Microchanneling Model
Prakash, Shashi^1 ; Kumar, Nitish^1 ; Kumar, Subrata^1
Mechanical Engineering Department, Indian Institute of Technology, Patna
801103, India^1
关键词: Laser beam parameters;    Micro-fluidic devices;    microchanneling;    PMMA;    Potential techniques;    Propagation of uncertainties;    sensitivity;    uncertainty;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/149/1/012125/pdf
DOI  :  10.1088/1757-899X/149/1/012125
来源: IOP
PDF
【 摘 要 】
CO2laser microchanneling has emerged as a potential technique for the fabrication of microfluidic devices on PMMA (Poly-methyl-meth-acrylate). PMMA directly vaporizes when subjected to high intensity focused CO2laser beam. This process results in clean cut and acceptable surface finish on microchannel walls. Overall, CO2laser microchanneling process is cost effective and easy to implement. While fabricating microchannels on PMMA using a CO2laser, the maximum depth of the fabricated microchannel is the key feature. There are few analytical models available to predict the maximum depth of the microchannels and cut channel profile on PMMA substrate using a CO2laser. These models depend upon the values of thermophysical properties of PMMA and laser beam parameters. There are a number of variants of transparent PMMA available in the market with different values of thermophysical properties. Therefore, for applying such analytical models, the values of these thermophysical properties are required to be known exactly. Although, the values of laser beam parameters are readily available, extensive experiments are required to be conducted to determine the value of thermophysical properties of PMMA. The unavailability of exact values of these property parameters restrict the proper control over the microchannel dimension for given power and scanning speed of the laser beam. In order to have dimensional control over the maximum depth of fabricated microchannels, it is necessary to have an idea of uncertainty associated with the predicted microchannel depth. In this research work, the uncertainty associated with the maximum depth dimension has been determined using Monte Carlo method (MCM). The propagation of uncertainty with different power and scanning speed has been predicted. The relative impact of each thermophysical property has been determined using sensitivity analysis.
【 预 览 】
附件列表
Files Size Format View
Monte-Carlo based Uncertainty Analysis For CO2 Laser Microchanneling Model 5566KB PDF download
  文献评价指标  
  下载次数:26次 浏览次数:58次