【 摘 要 】

The algorithm to produce primary radiographs, its transformation by dual energy method and recognition of the object materials were enhanced based on the analysis of experimental results. The experiments were carried out at the inspection complex with high X- ray source - betatron MIB 4/9 in Tomsk Polytechnic University. For the reduced X -ray dose rate, the possibility of recognition of the object materials with thickness from 20 to 120 g/cm2was proved under the condition that as the dose rate is reduced by the defined number of times, the segment of the image fragment with the reliably identified material will increase by the same number of times.