9th International Conference on 3D Radiation Dosimetry
Radiochromic and radiofluorogenic 3D solid polymer dosimeter: initial results for high doses
Rocío Bernal-Zamorano, María Del^1 ; Sanders, Nicolai Højer^1 ; René Lindvold, Lars^1 ; Andersen, Claus E.^1
Center for Nuclear Technologies, Technical University of Denmark, ROSKILDE
4000, Denmark^1
关键词: 3d dosimeters;    3d solids;    Absorbances;    Dose distributions;    High dose;    High spatial resolution;    Intensity-modulated radiation therapy;    Spatial resolution;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/847/1/012016/pdf
DOI  :  10.1088/1742-6596/847/1/012016
来源: IOP
PDF
【 摘 要 】

The complexity of dose distributions has increased with the advent of intensity modulated radiation therapy (IMRT). For that reason, experimental measurements using 3D dosimeters with high spatial resolution are required to check the delivered dose. In this study a new 3D solid polymer dosimeter with absorbance and fluorescence responses to radiation is presented. Measuring fluorescence instead of absorbance improves the spatial resolution and eases the read out of the dosimeter. The proposed dosimeter is tissue-equivalent and can be moulded in any shape by a controllable and fast photopolymerization process.

【 预 览 】
附件列表
Files Size Format View
Radiochromic and radiofluorogenic 3D solid polymer dosimeter: initial results for high doses 302KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:31次