3rd All-Russian Scientific and Practical Conference on Innovations in Non-Destructive Testing
Measurement Technique of Dose Rate Distribution of Ionization Sources with Unstable in Time Beam Parameters
Stuchebrov, S.G.^1 ; Miloichikova, I.A.^1 ; Danilova, I.B.^1
Tomsk Polytechnic University, Tomsk, Russia^1
关键词: Dose distributions;    Dose rate distributions;    Linear electron accelerator;    Measurement techniques;    Non destructive testing;    Position sensitive;    Radiation dose measurements;    Spatial resolution;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/671/1/012057/pdf
DOI  :  10.1088/1742-6596/671/1/012057
来源: IOP
PDF
【 摘 要 】

The article describes a new technique for the average values of radiation dose measurement for the unstable gamma-ray sources which are used in non-destructive testing. The method is based on usage of different types of compact accumulative dosimeters. Spatially distributed position sensitive dosimetry system based on compact sensitive elements was created. Size and spatial resolution of the system of the dosimetry system are chosen taking into account sources characteristics. The proposed method has been tested on the measurement of dose distribution of several sources of X-ray and gamma-radiation based on X-ray tubes, electronic accelerator betatrons and linear electron accelerators.

【 预 览 】
附件列表
Files Size Format View
Measurement Technique of Dose Rate Distribution of Ionization Sources with Unstable in Time Beam Parameters 699KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:26次