会议论文详细信息
3rd All-Russian Scientific and Practical Conference on Innovations in Non-Destructive Testing
Modernization of the X-Ray Tomographic Scanner Based on Gas-Discharge Linear Detector
Stuchebrov, S.G.^1 ; Batranin, A.V.^1 ; Miloichikova, I.A.^1
Tomsk Polytechnic University, Tomsk, Russia^1
关键词: Gas discharge;    Gas discharge detectors;    Linear detectors;    Multi channel;    Projection data;    Spatial resolution;    Tomographic data;    Volume of interest;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/671/1/012004/pdf
DOI  :  10.1088/1742-6596/671/1/012004
来源: IOP
PDF
【 摘 要 】

In this paper, we describe the modernization of the tomographic scanner based on multi-channel linear gas-discharge detector. We have changed the principle of acquisition the projection data, which allowed to receive a bulk three-dimensional tomographic data instead of single slices of the studied samples. Modified scanner has shown increasing contrast and spatial resolution of single slices. The volume of interest in studied objects has been significantly increased and are as high as 25 000 cubic cm, which is determined by 1536 pixels in high.

【 预 览 】
附件列表
Files Size Format View
Modernization of the X-Ray Tomographic Scanner Based on Gas-Discharge Linear Detector 1060KB PDF download