会议论文详细信息
12th International Conference on Gas Discharge Plasmas and Their Applications
Sterilization of dielectric containers using a fore-vacuum pressure plasma-cathode electron source
Zolotukhin, D.^1 ; Burdovitsini, V.^1 ; Oks, E.^1,2 ; Tyunkov, A.^1 ; Yushkov, Yu^1
Tomsk State University of Control Systems and Radioelectronics, Tomsk
634050, Russia^1
Institute of High Current Electronics SB RAS, Tomsk
634055, Russia^2
关键词: Bacterial suspensions;    Biological objects;    Cylindrical containers;    Electron beam source;    Gas compositions;    Inner surfaces;    Low energy electron beams;    Vacuum pressure;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/652/1/012044/pdf
DOI  :  10.1088/1742-6596/652/1/012044
来源: IOP
PDF
【 摘 要 】
We describe our work on sterilization of 10 ml glass and 60 ml plastic cylindrical containers using a fore-vacuum pressure, plasma-cathode, electron beam source. Beam plasma is formed inside the vessel by injection of a low-energy electron beam at 3 - 6 keV energy and current of 50 mA, at a working gas (air) pressure of 8 Pa. The gas composition was tracked by a quadrupole gas analyzer type RGA-100. As a test biological object for sterilization we used E. coli ATCC 25922 bacteria, the inner surface of each vessel was inoculated with a bacterial suspension. We find a smooth dependence of the degree of sterilization on the total energy density injected into the vessel. The efficacy of sterilization of container inner surfaces using a fore-vacuum pressure, plasma-cathode e-beam source of relatively low energy (a few keV) electrons is thus demonstrated.
【 预 览 】
附件列表
Files Size Format View
Sterilization of dielectric containers using a fore-vacuum pressure plasma-cathode electron source 1097KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:16次