会议论文详细信息
FAIR Next Generation ScientistS 2014
Verification of Electromagnetic Calorimeter Concept for the HADES spectrometer
Svoboda, O.^1 ; Blume, C.^2 ; Czyycki, W.^3 ; Epple, E.^4 ; Fabbietti, L.^4 ; Galatyuk, T.^5 ; Golubeva, M.^6 ; Guber, F.^6 ; Hlavá, S.^7 ; Ivashkin, A.^6 ; Kajetanowic, M.^8 ; Kardan, B.^2 ; Koenig, W.^9 ; Kugler, A.^1 ; Lapidus, K.^4 ; Linev, S.^9 ; Lisowski, E.^3 ; Ott, P.^11 ; Otte, P.^11 ; Petukhov, O.^6 ; Pietraszko, J.^9 ; Reshetin, A.^6 ; Rodríguez-Ramos, P.^1,10 ; Rost, A.^5 ; Salabura, P.^8 ; Skott, P.^11 ; Sobolev, Y.G.^1 ; Steffen, O.^11 ; Thomas, A.^11 ; Tlustý, P.^1 ; Traxler, M.^9
Nuclear Physics Institute, Academy of Sciences of the Czech Republic, e
250 68, Czech Republic^1
Institut für Kemphysik, Goethe-Universität, Frankfurt
60438, Germany^2
Institute of Technology Cracow, Cracow
31-155, Poland^3
Excellence Cluster 'Origin and Structure of the Universe, Technische Universität München, Garching
85748, Germany^4
Technische Universität Darmstadt, Darmstadt
64289, Germany^5
Institute for Nuclear Research, Russian Academy of Sciences, Moscow
117312, Russia^6
Institute of Physics, Slovak Academy of Sciences, Bratislava
845 11, Slovakia^7
Smoluchowski Institute of Physics, Jagiellonian University of Kraków, Cracow
30-59, Poland^8
GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt
64291, Germany
(10) Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Prague
115 19, Czech Republic
(11) Institut für Kernphysik, Johannes Gutenberg-Universität, Mainz
55128, Germany^9
关键词: Electromagnetic calorimeter;    Energy leakage;    Energy ranges;    Front end electronics;    Heavy ion collision;    Meson production;    Relative energies;    Technical solutions;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/599/1/012026/pdf
DOI  :  10.1088/1742-6596/599/1/012026
来源: IOP
PDF
【 摘 要 】

The HADES spectrometer currently operating on the beam of SIS18 accelerator in GSI will be moved to a new position in the CBM cave of the future FAIR complex. Electromagnetic calorimeter (ECAL) will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 A GeVon the beam of the new accelerator SIS100. Calorimeter will be based on 978 massive lead glass modules read out by photomultipliers and a novel front-end electronics. Secondary gamma beam with energies ranging from 81 MeV up to 1399 MeV from MAMI-C Mainz facility was used to verify selected technical solutions. Relative energy resolution was measured using modules with three different types of photomultipliers. Two types of developed front-end electronics as well as energy leakage between neighbouring modules under parallel and declined gamma beams were studied in detail.

【 预 览 】
附件列表
Files Size Format View
Verification of Electromagnetic Calorimeter Concept for the HADES spectrometer 982KB PDF download
  文献评价指标  