期刊论文详细信息
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS 卷:402
Geant4 simulations of the lead fluoride calorimeter
Article; Proceedings Paper
Savchenko, A. A.1  Tishchenko, A. A.1  Dabagov, S. B.1,2,4  Anastasi, A.2,3  Venanzoni, G.2,6  Strikhanov, M. N.1,6  Basti, A.14  Bedeschi, F.14  Bartolini, M.14  Cantatore, G.9  Cauz, D.11  Corradi, G.2  Di Sciascio, G.8  Di Stefano, R.7,12  Driutti, A.6,11  Escalante, O.10  Ferrari, C.2,5  Fioretti, A.5,14  Gabbanini, C.5,14  Gioiosa, A.16,17  Hampai, D.2  Iacovacci, M.7,10  Karuza, M.6,13  Liedl, A.2  Lusiani, A.14,15  Marignetti, F.7,12  Mastroianni, S.7  Moricciani, D.8  Pauletta, G.6,11  Piacentino, G. M.16,17  Raha, N.8  Santi, L.6 
[1] Natl Res Nucl Univ MEPhI, Moscow, Russia
[2] Ist Nazl Fis Nucl, Lab Nazl Frascati, Frascati, Italy
[3] Univ Messina, Dipartimento MIFT, Messina, Italy
[4] RAS, PN Lebedev Phys Inst, Moscow, Russia
[5] CNR, Ist Natl Ott, Pisa, Italy
[6] Ist Nazl Fis Nucl, Sez Trieste & GC Udine, Trieste, Italy
[7] Ist Nazl Fis Nucl, Sez Napoli, Naples, Italy
[8] Ist Nazl Fis Nucl, Sez Roma Tor Vergata, Rome, Italy
[9] Univ Trieste, Trieste, Italy
[10] Univ Naples Federico II, Naples, Italy
[11] Univ Udine, Udine, Italy
[12] Univ Cassino, Cassino, Italy
[13] Univ Rijeka, Rijeka, Croatia
[14] Ist Nazl Fis Nucl, Sez Pisa, Pisa, Italy
[15] Scuola Normale Super Pisa, Pisa, Italy
[16] Ist Nazl Fis Nucl, Sez Lecce, Lecce, Italy
[17] Univ Molise, Pesche, Italy
关键词: Lead-fluoride crystals;    Electromagnetic calorimeter;    Geant4 optical processes;    G-2 experiment;    Muon experiment;   
DOI  :  10.1016/j.nimb.2017.03.084
来源: Elsevier
PDF
【 摘 要 】

In this paper we simulate the charged particle interaction with complex structures, including the emission, with help of Geant4. We take into account Cherenkov radiation, transition radiation, bremsstrah-lung, pair production and other accompanying processes. As an application we investigate the full size electromagnetic calorimeter for the muon g-2 experiment at Fermilab. A calorimeter module consists of a Delrin front panel for installation of the laser calibration system, 54 PbF2 Cherenkov crystals wrapped by black Tedlar paper, and silicon photo-multiplier sensors. We report here on results of a simulation of the radiation from positrons striking the calorimeter system. The Cherenkov radiation expansion when a positron moves down through the calorimeter at the arbitrary angle of incidence has been considered. Both spectral and angular distributions of Cherenkov optical photons in different parts of the calorimeter system was evaluated as well as the transition radiation and pre-shower distributions from both the Delrin panel and the Al vacuum chamber of the g-2 storage ring. (C) 2017 Elsevier B.V. All rights reserved.