| 14th International Conference on Micro and Nanotechnology for Power Generation and Energy Conversion Applications | |
| IR Thermal Imaging Device using Photo-Patternable Temperature Sensitive Paint | |
| 物理学;能源学 | |
| Tsukamoto, T.^1 ; Wang, M.^1 ; Tanaka, S.^1 | |
| Department of Bioengineering and Robotics, Tohoku University, 6-6-01, Aoba Aza Aramaki, Aoba-ku, Miyagi, Sendai | |
| 980-8579, Japan^1 | |
| 关键词: Fabrication process; Infrared-to-visible; Plasma induced damage; Temperature sensitive paint; Thermal imaging applications; Thermal imaging devices; Transducer array; Transfer method; | |
| Others : https://iopscience.iop.org/article/10.1088/1742-6596/557/1/012066/pdf DOI : 10.1088/1742-6596/557/1/012066 |
|
| 来源: IOP | |
PDF
|
|
【 摘 要 】
This paper reports an infrared-to-visible transducer array made of temperature sensitive paint (TSP) for low-cost thermal imaging application. A novel fabrication process using a photo-patternable temperature sensitive paint (PTSP) combined with an SU-8 transfer method was developed. The developped process is simpler than before, and prevents the TSP structure from plasma-induced damage and sticking across a sacrificially-etched gap. The selfsuspended structure as small as 100 pm was successfully fabricated with a large gap of 40 μm from the substrate. The heated object of 300°C was detected with a resolution of about 0.4 mm.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| IR Thermal Imaging Device using Photo-Patternable Temperature Sensitive Paint | 1999KB |
PDF