会议论文详细信息
22nd International Congress on X-Ray Optics and Microanalysis
Wavefront preserving channel-cut optics for coherent x-ray scattering experiments at the P10 beamline at PETRAIII
Zozulya, A.V.^1 ; Shabalin, A.^1 ; Schulte-Schrepping, H.^1 ; Heuer, J.^1 ; Spiwek, M.^1 ; Sergeev, I.^1 ; Besedin, I.^1,2 ; Vartanyants, I.A.^1,2 ; Sprung, M.^1
Deutsches Elektronen-Synchrotron DESY, Notkestraße 85, 22607 Hamburg, Germany^1
National Research Nuclear University MEPhI, 115409 Moscow, Russia^2
关键词: Beam lines;    Beam stability;    Coherent X-ray scattering;    High quality;    Monochromator crystals;    PETRA III;    Si (1 1 1);    Synchrotron source;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/499/1/012003/pdf
DOI  :  10.1088/1742-6596/499/1/012003
来源: IOP
PDF
【 摘 要 】
We report on the performance of cryogenically cooled monolithic Si(111) channel-cut monochromator optics installed at the coherence beamline P10 of the PETRA III synchrotron source. Our results show that a high quality channel-cut monochromator crystal preserves the beam wavefront and provides excellent beam stability, which offers considerable benefits for coherent x-ray scattering experiments.
【 预 览 】
附件列表
Files Size Format View
Wavefront preserving channel-cut optics for coherent x-ray scattering experiments at the P10 beamline at PETRAIII 1470KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:26次