会议论文详细信息
3rd International Symposium on Resource Exploration and Environmental Science
Analysis and treatment of Free end vibration of condensate pump motor towards ultra-supercritical 660MW turbine
生态环境科学
Li, Wanjun^1 ; Li, Xiaoxia^2 ; Niu, Qingliang^1 ; Huang, Tianqi^1 ; Zhang, Deke^1 ; Dong, Yang^1
Huadian Electric Power Research Institute Co. LTD., Jinan
250014, China^1
CRRC Wind Power (Shandong)CO. Ltd, Jinan
250022, China^2
关键词: Abnormal vibration;    Condensate pumps;    Effective measures;    Field data;    Free end;    Inlet pipe;    Maintenance records;    Supercritical;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/300/4/042010/pdf
DOI  :  10.1088/1755-1315/300/4/042010
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

The motor free end vibrates at rated speed after overhaul of condensate pump; Through collecting field data and checking maintenance records, the fault diagnosis and troubleshooting of A condensate pump motor with excessive vibration was carried out based on the mechanism of vibration, and the cause of the fault was accurately analysed. By taking effective measures such as replacing the expansion joint at the inlet pipe, adjusting the concentricity of the pipes before and after the expansion joint, and adding A safety valve on the inlet pipe, the problem of excessive vibration of the condensate pump motor A has been thoroughly solved, and the hidden danger of equipment has been eliminated successfully.

【 预 览 】
附件列表
Files Size Format View
Analysis and treatment of Free end vibration of condensate pump motor towards ultra-supercritical 660MW turbine 784KB PDF download
  文献评价指标  
  下载次数:58次 浏览次数:45次