会议论文详细信息
2018 4th International Conference on Environmental Science and Material Application | |
Fault Diagnosis and treatment of Abnormal vibration of vertical condenser pump motor towards Ultra-supercritical 660MW turbo-generator set | |
生态环境科学;材料科学 | |
Li, Wanjun^1 ; Li, Xiaoxia^2 ; Huang, Tianqi^1 ; Niu, Qingliang^1 ; Zhang, Deke^1 ; Dong, Yang^1 | |
Huadian Electric Power Research Institute in Shandong Branch, Jinan | |
250014, China^1 | |
CRRC Wind Power (ShanDong) CO., LTD, Jinan | |
250022, China^2 | |
关键词: Abnormal vibration; Condensate pumps; Equipment safety; Magnetic force; Motor driving; No load; Pump motors; Supercritical; | |
Others : https://iopscience.iop.org/article/10.1088/1755-1315/252/3/032021/pdf DOI : 10.1088/1755-1315/252/3/032021 |
|
来源: IOP | |
【 摘 要 】
The motor driving end vibrates when there is no-load test run after overhaul of condensate pump of power plant unit; Through fault diagnosis and analysis, reasons for vibration were checked and solution found. The main reason is that the condensate pump motor magnetic force center line is not centered. The condensate pump motor is disassembled, then the reason of magnetic forcce center line is not centered was found and solution. Potential equipment safety hazard was eliminated successfully.【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Fault Diagnosis and treatment of Abnormal vibration of vertical condenser pump motor towards Ultra-supercritical 660MW turbo-generator set | 792KB | download |