会议论文详细信息
International Scientific and Practical Conference: Water Power Energy Forum 2018 | |
On-line express-analyzer and method of water monitoring on the base of proton magnetic resonance | |
Kashaev, R.S.^1 ; Kozelkov, O.V.^1 | |
Kazan State Power Engineering University, str. Krasnoselskaya, 51, Kazan | |
420066, Russia^1 | |
关键词: Express analyzer; Impurities in; Mode of operations; Nonuniform electric field; On-line controls; Removal of impurities; Water monitoring; | |
Others : https://iopscience.iop.org/article/10.1088/1755-1315/288/1/012035/pdf DOI : 10.1088/1755-1315/288/1/012035 |
|
来源: IOP | |
【 摘 要 】
Described flow analyzer of water on the presence of impurities, based on proton magnetic resonance - PMRA. Presented common appearance and construction, mode of operation PMR-analyzer. Presented equations of received dependences for determination of salts and oil impurities in water. Proposed structure and technologic schemes for removal of impurities from water in the installation with rotating magnetic and nonuniform electric field with continual on- line control of water purity bu flow PMR-analyzer..
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
On-line express-analyzer and method of water monitoring on the base of proton magnetic resonance | 1146KB | download |