Influence of different concentration of hydrogen peroxide on the corrosion behavior of Ti-6Al-4V alloy immersed in physiological solution
Ravoiu, A.^1^2 ; Simionescu, N.^1 ; Benea, L.^1
Competences Centre Interfaces-Tribocorrosion-Electrochemical Systems (CC-ITES), Dunarea de Jos University of Galati, 47 Domneasca Street, Galati
RO-800008, Romania^1
Faculty of Medicine and Pharmacy, Dunarea de Jos University of Galati, 35 Alexandru Ioan Cuza Street, Galati
800010, Romania^2
关键词: Commercially Pure titaniums;    ELectrochemical methods;    Hank's physiological solution;    Inflammatory conditions;    Mechanical behavior;    Open circuit potential;    Orthopedic applications;    Physiological solution;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/572/1/012006/pdf
DOI  :  10.1088/1757-899X/572/1/012006
来源: IOP
PDF
【 摘 要 】

The materials used as implants are expected to be highly non toxic and should not cause any inflammatory or allergic reactions in the human body. The success of the biomaterials is mainly dependent on the reaction of the human body to the implant. Titanium and some of its alloys are used as biomaterials for dental and orthopedic applications. The most common grades used are commercially pure titanium and the Ti-6Al-4V alloy. Frequent utilization of titanium and titanium alloys as biomaterials due to their superior biocompatibility, and high corrosion resistance as to form a thin surface oxide layer, and good mechanical properties, as a certain elastic modulus and low density that make that these metals present a mechanical behavior close to those of bones. Strong and totally biocompatible, titanium is one of the few materials that naturally match the requirements for implantation in the human body. Hydrogen peroxide appears in the human body when an inflammation occurs. This research work aims to assess the influence of different concentrations of hydrogen peroxide on the corrosion behavior of Ti-6Al-4V alloy submerged in Hank's physiological solution. Electrochemical methods as Open Circuit Potential and Electrochemical Impedance Spectroscopy were applied for corrosion investigations. The results provide evidence that Ti-6Al-4V corrosion resistance is affected by inflammatory conditions presence in Hank solution.