International Conference on Applied Sciences | |
An analyse on analogue ESR-meter | |
自然科学(总论) | |
Dini, C.M.^1 ; Popa, G.N.^1 ; Cunan, C.D.^1 ; Iagr, A.^1 | |
Politehnica University of Timisoara, Department of Electrical Engineering and Industrial Informatics, 5 Revolution Street, Hunedoara | |
331128, Romania^1 | |
关键词: Alternating voltages; Comparative analysis; Continuous voltages; Differential voltage; Measured values; Voltage amplifiers; Voltage-current converters; Wheatstone bridges; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/477/1/012031/pdf DOI : 10.1088/1757-899X/477/1/012031 |
|
学科分类:自然科学(综合) | |
来源: IOP | |
【 摘 要 】
The paper presents an analogue ESR meter, made with a JFET integrated circuit, which can be used to identify defective electrolytic capacitors. It is powered by continuous voltage and consists of a differential voltage source, a 100 kHz oscillator, a Wheatstone bridge with resistors supplied with alternating voltage, in a connecting arm of bridge being connected the electrolytic capacitors to be checked, a voltage amplifier-comparator with optical warning, a high-pass filter and a voltage-current converter. At the output of voltage-current converter is a milliammeter pointing out the ESR value (up to 20 Ω). Measurements were made on a batch of electrolytic capacitors (new and used) and a comparative analysis was performed between the measured values with an analogue ESR-meter and a digital one.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
An analyse on analogue ESR-meter | 1060KB | download |