学位论文详细信息
A piezoresistive microcantilever array for chemical sensing applications
Surface stress;Chemical sensor;Piezoresistive;Microcantilever;Sensor array
Choudhury, Arnab ; Mechanical Engineering
University:Georgia Institute of Technology
Department:Mechanical Engineering
关键词: Surface stress;    Chemical sensor;    Piezoresistive;    Microcantilever;    Sensor array;   
Others  :  https://smartech.gatech.edu/bitstream/1853/26623/1/Choudhury_Arnab_200712_phd.pdf
美国|英语
来源: SMARTech Repository
PDF
【 摘 要 】

Numerous applications in the present day ranging from testing humidity in air to detecting miniscule quantities of potentially hazardous chemical and biological agents in the air or water supplies require the development of chemical sensors capable of analyte detection with high sensitivity and selectively. Further, it has become desirable to create lab-on-chip systems that can detect multiple chemical agents and allow for sampling and testing of environments at locations distant from conventional laboratory facilities. Current challenges in this area include design, development and characterization of low detection limit sensors, development of low-noise readout methods, positive identification of analytes and, identification and reduction of the effect of various noise sources - both intrinsic and extrinsic to the sensor. The current work examines the performance limits of a 10-cantilever piezoresistive microcantilever array (PµCA) sensor. The microcantilevers measure analyte concentration in terms of the surface stress associated with analyte binding to the functionalized cantilever surface.The design, fabrication, characterization and testing of this measurement platform is presented. A novel aspect of the sensors developed is the use of n-type doping which increases the sensitivity of the device by one order of magnitude. In addition, design rules for surface stress-based chemical sensors have been developed. Extensive thermal characterization of the piezoresistive microcantilevers has been performed for DC and AC electrical excitation and values of heat transfer coefficient for the associated microscale phenomena are reported. Further, a method of low-noise measurement of cantilever resistance has been developed based on phase-sensitive detection techniques and this has been integrated with a multiplexing circuit to measure piezoresistance change in multiple cantilevers. Finally, the two novel techniques of chemical sensing- double-sided sensing and thermal array-based sensing have been investigated. These methods are presented as a means of extending the applicability and functionality of piezoresistive microcantilever sensors for chemical sensing.

【 预 览 】
附件列表
Files Size Format View
A piezoresistive microcantilever array for chemical sensing applications 19978KB PDF download
  文献评价指标  
  下载次数:20次 浏览次数:16次