学位论文详细信息
Limited Angle Ultrasound Tomography of the Compressed Breast
ultrasound tomography;breast imaging;Biomedical Engineering;Engineering;Biomedical Engineering
Jintamethasawat, RungrojFessler, Jeffrey A ;
University of Michigan
关键词: ultrasound tomography;    breast imaging;    Biomedical Engineering;    Engineering;    Biomedical Engineering;   
Others  :  https://deepblue.lib.umich.edu/bitstream/handle/2027.42/143944/rungroj_1.pdf?sequence=1&isAllowed=y
瑞士|英语
来源: The Illinois Digital Environment for Access to Learning and Scholarship
PDF
【 摘 要 】

X-ray mammography is widely accepted as the clinical standard for breast cancer screening and diagnosis. However, reflection mode ultrasound has been known to outperform x-ray in screening performance in dense breasts. With newer modes of ultrasound, acoustic properties of breast tissue, such as the speed of sound and attenuation coefficient distributions, can be extracted from captured ultrasound signals and used to characterize breast tissue types and contribute to detection and diagnosis of malignancy. The same is possibly true for optical absorption via photoacoustic imaging. Recently, we have developed a dual-sided ultrasound scanner that can be integrated with existing x-ray mammographic systems and acquire images in the mammographic view and compression. Transmission imaging for speed of sound and attenuation coefficient in this geometry is termed limited angle tomography, as the beams at frequencies yielding high resolution cannot transit the long axis of the compressed breast. This approach, ideally, should facilitate the co-registration and comparisons between images from three modalities discussed here (x-ray, ultrasound and photoacoustic) and increase diagnostic detection confidence. However, potential limitations inherent in limited angle tomography have received minimal exploration up to this study, and existing imaging techniques developed for this approach are based on overly optimistic assumptions that hinder achievement of the desired image quality. This investigation of these problems should contribute valuable information to the validation and translation of the mammographically-configured, dual-sided ultrasound, or ultrasound and photoacoustic, scanner to the clinic.This dissertation first aims to extensively identify possible sources of error resulting from imaging in the limited angle tomography approach. Simulation findings mapping parametric conditions reveal that image artifacts arising in reflection mode (B-mode) can be modulated or mitigated by ultrasound gels with adequate acoustic properties.In addition, sound speed imaging was performed determining the level of significance for several key sources of error.Results suggest that imaging in transmission mode is the most sensitive to transducer misplacement in the signal propagation direction. This misplacement, however, could be minimized easily by routinely calibrating transducer positions.Next, this dissertation aims to advance speed of sound, attenuation, and photoacoustic image reconstruction algorithms for the limited angle tomography approach. This was done by utilizing both structural information of the imaged objects/tissues by means of the corresponding reflection mode images taken from the same imaging location, and a full acoustic modeling framework to account for complex acoustic interactions within the field of view. We have shown through simulations that both a priori information from reflection mode images and full acoustic modeling contribute to a noticeable improvement in the reconstructed images. Work done throughout the course of this dissertation should provide a foundation and insight necessary for improvements upon the existing dual-sided ultrasound scanner towards breast imaging in the clinic.

【 预 览 】
附件列表
Files Size Format View
Limited Angle Ultrasound Tomography of the Compressed Breast 12337KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:24次