This work is to utilize the superior characteristics of polymer microring resonators in ultrasound detection to push the application of photoacoustic imaging to an entirely new level.We first demonstrated significantly improved imaging quality for photoacoustic tomography (PAT) using microring detectors. For wideband PAT, the microring detectors were able to faithfully detect both the boundaries and the inner structure, while piezoelectric detectors can only preserve one of the two aspects. For high-resolution PAT over a large imaging area, we imaged 50 µm black beads and found that microrings produced high-resolution imaging over a 16-mm-diameter imaging area while the 500 µm piezoelectric detectors only obtained high-resolution imaging over a small area around center.Pure optical photoacoustic microscopy (PAM) has been demonstrated. Microring ultrasonic resonators were applied in in vivo photoacoustic imaging for the first time. Good imaging signal-to-noise ratio and high axial resolution of 8 µm were calibrated. As a comparison, a commercial hydrophone with similar sensitivity produced a low axial resolution of 105 µm.A 5 mm miniaturized probe consisting of a fiber to deliver excitation laser pulses and microring detectors for ultrasound detection has been fabricated for photoacoustic endoscopy. The calibrated high radial resolution of 21 µm was higher than other types of endoscopic photoacoustic probes, around 40 µm or larger.A photoacoustic correlation spectroscopy (PACS) technique was proposed. In a proof-of-concept experiment, we demonstrated low-speed flow measurement of ~15 µm/s by the PACS technique. We also demonstrated in vivo flow speed measurement of red blood cells in capillaries in a chick embryo model by PACS. Other techniques might have difficulties to measure it due to the low signal contrast and/or poor resolutions.We also proposed terahertz electromagnetic pulse detection by photoacoustic method. We used carbon nanotube composites as efficient photoacoustic transmitters and microrings as sensitive detectors. The photoacoustic method provides low-cost and real-time terahertz detection (~µs), which is difficult by conventional terahertz detectors, such as a bolometer or a pyroelectric detector.
【 预 览 】
附件列表
Files
Size
Format
View
Optical Microring Resonators for Photoacoustic Imaging and Detection.