科技报告详细信息
Trunnion Collar Removal Machine-Gap Analysis Table.
Faillace, E.
Technical Information Center Oak Ridge Tennessee
关键词: Radioactive waste management;    Design;    Performance;    Radioactive waste facilities;    Safety standards;   
RP-ID  :  DE2006850445
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

The purpose of this document is to review the existing the trunnion collar removal machine against the 'Nuclear Safety Design Bases for License Application' (NSDB) requirements and to identify codes and standards and supplemental requirements to meet these requirements. If these codes and standards can not fully meet these requirements then a gap is identified. These gaps will be identified here and addressed using the 'Trunnion Collar Removal Machine Design Development Plan'. The codes and standards, supplemental requirements, and design development requirements for the trunnion collar removal machine are provided in the gap analysis table. Because the trunnion collar removal machine is credited with performing functions important to safety (ITS) in the NSDB, design basis requirements are applicable to ensure equipment is available and performs required safety functions when needed. The gap analysis table is used to identify design objectives and provide a means to satisfy safety requirements.

【 预 览 】
附件列表
Files Size Format View
DE2006850445.pdf 4846KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:1次