This report evaluates Enhanced Design Alternative (EDA) IV as part of the second phase of the License Application Design Selection (LADS) effort. The EDA IV concept was compared to the VA reference design using criteria from the 'Design Input Request for LADS Phase II EDA Evaluations' (CRWMS M&O 1999b) and (CRWMS M&O 1999f). Briefly, the EDA IV concept arranges the waste packages close together in an emplacement configuration known as 'line load'. Continuous pre-closure ventilation keeps the waste packages from exceeding the 350 C cladding and 200 C (4.3.13) drift wall temperature limits. This EDA concept keeps relatively high, uniform emplacement drift temperatures (post-closure) to drive water away from the repository and thus dry out the pillars between emplacement drifts. The waste package is shielded to permit human access to emplacement drifts and includes an integral filler inside the package to reduce the amount of water that can contact the waste form. Closure of the repository is desired 50 years after first waste is emplaced. Both backfill and a drip shields will be emplaced at closure to improve post-closure performance.