Radioactive Air Emissions Notice of Construction for the 300 Area Process Sewer Cleanout.
Technical Information Center Oak Ridge Tennessee
关键词: Hanford Reservation;    Cleaning;    Air pollution control;    Waste water;    Radionuclides;   
RP-ID  :  DE2003803920
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

This document serves as a NOC pursuant to the requirements of Washington Administrative Code (WAC) 246-247-060, and as a request for approval to construct pursuant to 40 Code of Federal Regulations (CFR) 61.07, for the cleanout of sections of the 300 Area PS. Approval of the NOC will allow the pressure washing of certain pipe sections, the sump in the TEDF lift station, and the cleaning of PS 16 of the 300 Area PS that contains low levels of radioactivity. Section 15.0 of this NOC discusses the estimated total effective dose equivalent (TEDE) to the offsite maximally exposed individual (MEI) resulting from the unabated emissions from these cleaning activities. Using the currently approved unit dose conversion factors in HNF-3602, the estimated potential TEDE to the MEI resulting from the unabated, fugitive emissions from cleanout of the 300 Area PS is 4.70 E-05 millirem (mrem) per year. This dose was derived by conservatively estimating the doses from both the pressure washing and the use of the Guzzler(trademark) for removal of the liquid/soil mixture, as described in Section 5.0. and adding these doses together.