科技报告详细信息
Water Consumption from Freeze Protection Valves for Solar Water Heating Systems.
Burch, J. ; Salasovich, J.
Technical Information Center Oak Ridge Tennessee
关键词: Solar water heating;    Water consumption;    Freeze protection;    Valves;    Domestic water;   
RP-ID  :  DE2006875327
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】
Freeze protection valves (FPV) have been used in direct solar domestic water heating systems (SDWH) in mild climates to prevent freeze damage of the collector. Pipe freezing in passive systems can also be prevented using these valves. A limiting factor on where FPVs might be used is the amount of water consumed through use of the valve. An experiment was performed to determine the average flow rate through FPVs over a range of air and water supply temperatures. The experimental flow rate data was then used in a simulation to determine the annual flow through FPVs for 215 sites throughout the continental United States. A correlation between the annual flow and the site air-freezing index (AFI) was then developed in order to increase the spatial data density to over 3,300 sites using AFI data. U.S. maps were generated to display the results graphically. The maps show that there is great potential to increase the market of direct and passive SDWH by using FPV versus using pipe insulation only, although valve reliability remains a concern.
【 预 览 】
附件列表
Files Size Format View
DE2006875327.pdf 660KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:39次