科技报告详细信息
High Level Waste Demonstration of the Caustic-Side Solvent Extraction Process with Optimized Solvent in the 2-CM Centrifugal Contactor Apparatus Using Tank 37H/44F Supernate.
Norato, M. A. ; Campbell, S. G. ; Crowder, M. L. ; Geeting, M. W. ; Kessinger, G. F. ; Pierce, R. A. ; Walker, D. D.
Technical Information Center Oak Ridge Tennessee
关键词: High-level radioactive wastes;    Solvent extraction;    Chemistry;    Decontamination;    Centrifuges;   
RP-ID  :  DE2003807668
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

Researchers at the Savannah River Technology Center (SRTC) successfully demonstrated the chemistry of the Caustic-Side Solvent Extraction (CSSX) flow sheet for the decontamination of high level waste using an optimized solvent in a 33-stage, 2-cm centrifugal contactor apparatus. This represents the second CSSX process demonstration using Savannah River Site (SRS) high level waste (HLW). Three tests were performed using radioactively 'spiked' simulated Tank 37H/44F composite waste, and a 24-hour demonstration was performed using actual Tank 37H/44F composite HLW supernate.

【 预 览 】
附件列表
Files Size Format View
DE2003807668.pdf 496KB PDF download