科技报告详细信息
| High Level Waste Demonstration of the Caustic-Side Solvent Extraction Process with Optimized Solvent in the 2-CM Centrifugal Contactor Apparatus Using Tank 37H/44F Supernate. | |
| Norato, M. A. ; Campbell, S. G. ; Crowder, M. L. ; Geeting, M. W. ; Kessinger, G. F. ; Pierce, R. A. ; Walker, D. D. | |
| Technical Information Center Oak Ridge Tennessee | |
| 关键词: High-level radioactive wastes; Solvent extraction; Chemistry; Decontamination; Centrifuges; | |
| RP-ID : DE2003807668 | |
| 学科分类:工程和技术(综合) | |
| 美国|英语 | |
| 来源: National Technical Reports Library | |
PDF
|
|
【 摘 要 】
Researchers at the Savannah River Technology Center (SRTC) successfully demonstrated the chemistry of the Caustic-Side Solvent Extraction (CSSX) flow sheet for the decontamination of high level waste using an optimized solvent in a 33-stage, 2-cm centrifugal contactor apparatus. This represents the second CSSX process demonstration using Savannah River Site (SRS) high level waste (HLW). Three tests were performed using radioactively 'spiked' simulated Tank 37H/44F composite waste, and a 24-hour demonstration was performed using actual Tank 37H/44F composite HLW supernate.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| DE2003807668.pdf | 496KB |
PDF