Actinide Measurements by Accelerator Mass Spectrometry at Lawrence Livermore National Laboratory. | |
Brown, T. A. ; Marchetti, A. A. ; Maretinelli, R. E. ; Cox, C. C. | |
Technical Information Center Oak Ridge Tennessee | |
关键词: Accelerator mass spectrometry; Mass spectrometry; Actinides; Lawrence Livermore National Laboratory; Measurements; | |
RP-ID : DE200515014369 | |
学科分类:工程和技术(综合) | |
美国|英语 | |
来源: National Technical Reports Library | |
【 摘 要 】
We report on the development of an accelerator mass spectrometry (AMS) system for the measurement of actinides at Lawrence Livermore National Laboratory. This AMS system is centered on a recently completed heavy isotope beam line that was designed particularly for high sensitivity, robust, high-throughput measurements of actinide concentrations and isotopic ratios. A fast isotope switching capability has been incorporated in the system, allowing flexibility in isotope selection and for the quasi-continuous normalization to a reference isotope spike.