Prior to and during the design of the APSs Access Control Interlock System (ACIS), an effort was made to insure that the design complied with the relevant DOE and ANL requirements as well as those set forth in other recognized documents then in circulation. A paragraph-by-paragraph listing of the requirements (in some cases, recommended practices) and the corresponding ACIS design features was compiled for use by the review committees then in place. This tabulation was incorporated in the APS Safety Analysis Document (SAD) as Appendix A. With the evolutionary changes that have occurred to the APS and to the documents referenced, some of the details of these compliances have evolved as well. It has been decided to maintain the SAD as a living document, editing it in close time proximity to the evolving APS. Since Appendix A depicted the ACISs original design compliance to an also-evolving set of documents, it was decided to remove Appendix A but to retain it as a reference document. This LS Note now contains that set of original design compliances. As the APS and the ACIS continue to evolve, the changes made will be subject to internal review and approval and will always be subject to the requirements set forth by the DOE and ANL.