This paper describes the derivation of analytic expressions for the angular resolution of reconstructing gamma rays detected via Compton interactions. We consider two types of gamma-ray detectors: Compton-ring and electron-tracking devices. In Compton-ring devices, the direction of the scattered electron is not resolved, only the total energy (electron and scattered photon) and the scattered photon direction are measured. The measured quantities define a cone about the axis of the scattered photon direction. The initial photon direction lies along this cone. Thus for single events there is a ring-like ambiguity in the photon direction. By combining multiple events, the intersection of the reconstructed rings will resolve the initial direction of the photon source. In this paper, we derive the resolution of the cone angle for individual rings.