Development and Characterization of a High-Efficiency, Aircraft-Based Axial Cyclone Cloud Water Collector
Crosbie, Ewan ; Brown, Matthew ; Shook, Michael [Point of Contact] ; Ziemba, Luke ; Moore, Richard H ; Shingler, Taylor ; Winstead, Edward ; Thornhill, K Lee ; Robinson, Claire ; Macdonald, Alexander B(Arizona Univ, Tucson, AZ, United States)
关键词: AIR SAMPLING;    AIRCRAFT DESIGN;    AIRCRAFT PERFORMANCE;    C-130 AIRCRAFT;    CLOUDS (METEOROLOGY);    COMPUTATIONAL FLUID DYNAMICS;    CYCLONES;    DROPS (LIQUIDS);    ESTIMATES;    TRACE ELEMENTS;    WATER SAMPLING;   
RP-ID  :  NF1676L-29808
美国|英语
来源: NASA Technical Reports Server
PDF
【 摘 要 】

A new aircraft-mounted probe for collecting samples of cloud water has been designed, fabricated and extensively tested. Following previous designs, the probe uses inertial separation to remove cloud droplets from the airstream, which are subsequently collected and stored for offline analysis. We report details of the design, operation, and the modeled and measured probe performance. Computational Fluid Dynamics (CFD) was used to understand the flow patterns around the complex interior geometrical features that were optimized to ensure efficient capture of droplets. CFD simulations coupled with particle tracking and multiphase surface transport modeling provide detailed estimates of the probe performance across the entire range of flight operating conditions and sampling scenarios. Physical operation of the probe was tested on a Lockheed C130 Hercules (fuselage mounted) and de Havilland Twin Otter (wing pylon mounted) during three field campaigns. During C130 flights on the final field campaign, the probe reflected the most developed version of the design and a median sample collection rate of 4.5 ml min-1 was achieved. This allowed samples to be collected over 1-2 minutes under optimal cloud conditions. Flights on the Twin Otter featured an intercomparison of the new probe with the slotted-rod collector; an existing technique for collecting cloud water. Comparison of trace species concentrations showed a good agreement between collection techniques, with absolute concentrations of most major ions agreeing within 30%, on average, despite sampled concentrations ranging over several orders of magnitude and the samples not collected with perfect coincidence.

【 预 览 】
附件列表
Files Size Format View
20190028837.pdf 830KB PDF download
  文献评价指标  
  下载次数:23次 浏览次数:12次