Transmission Grating Measurements of Undulator K | |
Bionta, R. M. | |
SLAC National Accelerator Laboratory | |
关键词: Xfel; 43 Particle Accelerators; Free Electron Lasers; X-Ray Spectra; Wiggler Magnets; | |
DOI : 10.2172/993726 RP-ID : SLAC-TN-10-064 RP-ID : AC02-76SF00515 RP-ID : 993726 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
This study was undertaken to understand the practicalities of determine K differences in the undulator modules by measuring single-shot x-ray spectra of the spontaneous radiation with a transmissive grating spectrometer under development to measure FEL spectra. Since the quality of the FEL is dependent on a uniform K value in all the undulator modules, being able to measure the relative undulator K values is important. Preliminary results were presented in a presentation, 'Use of FEL Off-Axis Zone Plate Spectrometer to Measure Relative K by the Pinhole/Centroid Method', at the 'LCLS Beam-Based Undulator K Measurements Workshop' on November 14, 2005 (UCRL-PRES-217281). This study applies equally well to reflective gratings of the appropriate period and inclinations.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
993726.pdf | 184KB | download |