EFFECTS OF TEMPERATURE AND CONTAMINATION ON MPCMS ELECTRODES IN 241-AY-101 AND 241-AN-107 TANK WASTE SIMULANTS
DM, CATO ; MM, DAHL ; GL, PHILO ; GL, EDGEMON ; DR.JLS, BELL ; CG, MOORE
Hanford Site (Wash.)
关键词: Corrosion;    Radioactive Waste Storage;    Monitoring;    Corrosive Effects;    Electrodes;   
DOI  :  10.2172/978605
RP-ID  :  RPP-RPT-44463 Rev 0
RP-ID  :  DE-AC27-08RV14800
RP-ID  :  978605
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This report documents the results of tests designed to characterize the relationship between temperature and the measured potential of electrodes installed on multi-probe corrosion monitoring systems in waste tanks. This report also documents the results of tests designed to demonstrate the impact of liquid in-leakage into electrode bodies as well as the contamination of primary reference electrodes by diffusion through the electrode tip.