Acceptance Test Report for Fourth-Generation Hanford Corrosion Monitoring Cabinet | |
NORMAN, E.C. | |
Lockheed Martin Hanford Corporation | |
关键词: Corrosion; Safety Engineering; Radioactive Waste Storage; Monitoring; Performance Testing; | |
DOI : 10.2172/805387 RP-ID : RPP-7035, Rev.0 RP-ID : AC27-99RL14047 RP-ID : 805387 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
This Acceptance Test Plan (ATP) will document the satisfactory operation of the third-generation corrosion monitoring cabinet (Hiline Engineering Part No.0004-CHM-072-C01). This ATP will be performed by the manufacturer of the cabinet prior to delivery to the site. The objective of this procedure is to demonstrate and document the acceptance of the corrosion monitoring cabinet. The test will consist of a continuity test of the cabinet wiring from the end of cable to be connected to corrosion probe, through the appropriate intrinsic safety barriers and out to the 15 pin D-shell connectors to be connected to the corrosion monitoring instrument. Additional testing will be performed using a constant current and voltage source provided by the corrosion monitoring hardware manufacturer to verify proper operation of corrosion monitoring instrumentation.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
805387.pdf | 263KB | download |