科技报告详细信息
Savannah River Site/K Area Complex getter life extension report.
Shepodd, Timothy J. ; Woodsmall, Todd (Savannah River Site, Aiken, SC) ; Nissen, April
Sandia National Laboratories
关键词: Aging;    Storage;    Getters;    Oxygen;    Recombination;   
DOI  :  10.2172/948330
RP-ID  :  SAND2008-5530
RP-ID  :  AC04-94AL85000
RP-ID  :  948330
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The K Area Complex (KAC) at the Savannah River Site (SRS) has been utilizing HiTop hydrogen getter material in 9975 Shipping Containers to prevent the development of flammable environments during storage of moisture-containing plutonium oxides. Previous testing and subsequent reports have been performed and produced by Sandia National Laboratories (SNL) to demonstrate the suitability and longevity of the getter during storage at bounding thermal conditions. To date, results have shown that after 18 months of continuous storage at 70 C, the getter is able to both recombine gaseous hydrogen and oxygen into water when oxygen is available, and irreversibly getter (i.e. scavenge) hydrogen from the vapor space when oxygen is not available, both under a CO{sub 2} environment. [Refs. 1-5] Both of these reactions are catalytically enhanced and thermodynamically favorable. The purpose of this paper is to establish the justification that maintaining the current efforts of biannual testing is no longer necessary due to the robust performance of the getter material, the very unlikely potential that the recombination reaction will fail during storage conditions in KAC, and the insignificant aging effects that have been seen in the testing to date.

【 预 览 】
附件列表
Files Size Format View
948330.pdf 799KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:20次