科技报告详细信息
Measurements and corrections of the Recycler lattice at Fermilab
Xiao, Meiqin
Fermi National Accelerator Laboratory
关键词: 43 Particle Accelerators;    Tuning Accelerators;    Accelerators;    Magnets;    Optics;   
DOI  :  10.2172/940423
RP-ID  :  FERMILAB-TM-2412-AD
RP-ID  :  AC02-07CH11359
RP-ID  :  940423
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Obit Response Matrix (ORM) Fit method has been successfully used to calibrate linear optics at Recycler Ring at Fermilab. The linear model of the Recycler optics ring has been significantly improved. Based on the build-up model, lattice measurement of the Recycler ring has been done several times, each after some magnets move and the tunes change. Large beta-wave({approx}20%) has been found in horizontal plane after the working point was moved from (0.424,0.434) to (0.456, 0.467) for the reason of lowering the beam instabilities. The source of the beta-wave, and the correction will be presented in this paper. In addition, we found an easy way to extend the tuning range in the recycler lattice. A new application program for adjusting the tunes operationally was introduced and the measured results will be presented.

【 预 览 】
附件列表
Files Size Format View
940423.pdf 2969KB PDF download
  文献评价指标  
  下载次数:27次 浏览次数:20次