科技报告详细信息
Laser hazard analysis for airborne AURA (Big Sky variant) Proteus platform.
Augustoni, Arnold L.
Sandia National Laboratories
关键词: Calibration;    Personnel;    Sky;    Opacity;    61 Radiation Protection And Dosimetry;   
DOI  :  10.2172/918320
RP-ID  :  SAND2004-0413
RP-ID  :  AC04-94AL85000
RP-ID  :  918320
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

A laser safety and hazard analysis was performed for the airborne AURA (Big Sky Laser Technology) lidar system based on the 2000 version of the American National Standard Institute's (ANSI) Standard Z136.1, for the Safe Use of Lasers and the 2000 version of the ANSI Standard Z136.6, for the Safe Use of Lasers Outdoors. The AURA lidar system is installed in the instrument pod of a Proteus airframe and is used to perform laser interaction experiments and tests at various national test sites. The targets are located at various distances or ranges from the airborne platform. In order to protect personnel, who may be in the target area and may be subjected to exposures, it was necessary to determine the Maximum Permissible Exposure (MPE) for each laser wavelength, calculate the Nominal Ocular Hazard Distance (NOHD), and determine the maximum 'eye-safe' dwell times for various operational altitudes and conditions. It was also necessary to calculate the appropriate minimum Optical Density (ODmin) of the laser safety eyewear used by authorized personnel who may receive hazardous exposures during ground base operations of the airborne AURA laser system (system alignment and calibration).

【 预 览 】
附件列表
Files Size Format View
918320.pdf 693KB PDF download