MOX Fabrication Isolation Considerations | |
Shaber, Eric L. ; Schrader, Bradley J | |
Idaho National Laboratory | |
关键词: Mox; 11 - Nuclear Fuel Cycle And Fuel Materials; Oxides; Fuel Cycle; Manufacturing; | |
DOI : 10.2172/911246 RP-ID : INL/EXT-05-00587 RP-ID : DE-AC07-99ID-13727 RP-ID : 911246 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
This document provides a technical position on the preferred level of isolation to fabricate demonstration quantities of mixed oxide transmutation fuels. The Advanced Fuel Cycle Initiative should design and construct automated glovebox fabrication lines for this purpose. This level of isolation adequately protects the health and safety of workers and the general public for all mixed oxide (and other transmutation fuel) manufacturing efforts while retaining flexibility, allowing parallel development and setup, and minimizing capital expense. The basis regulations, issues, and advantages/disadvantages of five potential forms of isolation are summarized here as justification for selection of the preferred technical position.