科技报告详细信息
MOX Fabrication Isolation Considerations
Shaber, Eric L. ; Schrader, Bradley J
Idaho National Laboratory
关键词: Mox;    11 - Nuclear Fuel Cycle And Fuel Materials;    Oxides;    Fuel Cycle;    Manufacturing;   
DOI  :  10.2172/911246
RP-ID  :  INL/EXT-05-00587
RP-ID  :  DE-AC07-99ID-13727
RP-ID  :  911246
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This document provides a technical position on the preferred level of isolation to fabricate demonstration quantities of mixed oxide transmutation fuels. The Advanced Fuel Cycle Initiative should design and construct automated glovebox fabrication lines for this purpose. This level of isolation adequately protects the health and safety of workers and the general public for all mixed oxide (and other transmutation fuel) manufacturing efforts while retaining flexibility, allowing parallel development and setup, and minimizing capital expense. The basis regulations, issues, and advantages/disadvantages of five potential forms of isolation are summarized here as justification for selection of the preferred technical position.

【 预 览 】
附件列表
Files Size Format View
911246.pdf 265KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:18次