科技报告详细信息
Power Systems Development Facility
Southern Co Services Inc
关键词: 30 Direct Energy Conversion;    Particulates;    Testing;    Gasification;    Oxygen;   
DOI  :  10.2172/908322
RP-ID  :  None
RP-ID  :  FC21-90MC25140
RP-ID  :  908322
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This report discusses Test Campaign TC12 of the Kellogg Brown & Root, Inc. (KBR) Transport Gasifier train with a Siemens Westinghouse Power Corporation (SW) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Gasifier is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using a particulate control device (PCD). While operating as a gasifier, either air or oxygen can be used as the oxidant. Test run TC12 began on May 16, 2003, with the startup of the main air compressor and the lighting of the gasifier start-up burner. The Transport Gasifier operated until May 24, 2003, when a scheduled outage occurred to allow maintenance crews to install the fuel cell test unit and modify the gas clean-up system. On June 18, 2003, the test run resumed when operations relit the start-up burner, and testing continued until the scheduled end of the run on July 14, 2003. TC12 had a total of 733 hours using Powder River Basin (PRB) subbituminous coal. Over the course of the entire test run, gasifier temperatures varied between 1,675 and 1,850 F at pressures from 130 to 210 psig.

【 预 览 】
附件列表
Files Size Format View
908322.pdf 6413KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:16次